Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Book Review
Brief Report
Case Letter
Case Report
Case Series
Commentary
Current Issue
Editorial
Erratum
Guest Editorial
Images
Images in Neurology
Images in Neuroscience
Images in Neurosciences
Letter to Editor
Letter to the Editor
Letters to Editor
Letters to the Editor
Media and News
None
Notice of Retraction
Obituary
Original Article
Point of View
Position Paper
Review Article
Short Communication
Systematic Review
Systematic Review Article
Technical Note
Techniques in Neurosurgery
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Book Review
Brief Report
Case Letter
Case Report
Case Series
Commentary
Current Issue
Editorial
Erratum
Guest Editorial
Images
Images in Neurology
Images in Neuroscience
Images in Neurosciences
Letter to Editor
Letter to the Editor
Letters to Editor
Letters to the Editor
Media and News
None
Notice of Retraction
Obituary
Original Article
Point of View
Position Paper
Review Article
Short Communication
Systematic Review
Systematic Review Article
Technical Note
Techniques in Neurosurgery
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Book Review
Brief Report
Case Letter
Case Report
Case Series
Commentary
Current Issue
Editorial
Erratum
Guest Editorial
Images
Images in Neurology
Images in Neuroscience
Images in Neurosciences
Letter to Editor
Letter to the Editor
Letters to Editor
Letters to the Editor
Media and News
None
Notice of Retraction
Obituary
Original Article
Point of View
Position Paper
Review Article
Short Communication
Systematic Review
Systematic Review Article
Technical Note
Techniques in Neurosurgery
View/Download PDF

Translate this page into:

Original Article
10 (
2
); 178-184
doi:
10.4103/jnrp.jnrp_370_18

Developing Normative Reference Values for Nerve Conduction Studies of Commonly Tested Nerves among a Sample Pakistani Population

Department of Neurophysiology, Aga Khan University Hospital, Karachi, Pakistan
Department of Medicine, Aga Khan University Hospital, Karachi, Pakistan
Address for correspondence: Dr. Sara Khan, Department of Neurophysiology (Neurology), Aga Khan University Hospital, Karachi, Pakistan. E-mail: sara.khan@aku.edu
Licence

This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.

Disclaimer:
This article was originally published by Wolters Kluwer - Medknow and was migrated to Scientific Scholar after the change of Publisher.

Abstract

Introduction:

Most neurophysiology departments around the world establish their own normative data. However, ethnic differences are not taken into account. Our aim was to establish normal nerve conduction studies (NCS) data for routinely tested nerves in individuals of Pakistani (South Asian) origin and to compare with Western published data.

Materials and Methods:

One hundred healthy adults’ nerves were assessed, using standardized techniques. Individuals were grouped into age groups. Gender differences were assessed.

Results:

Of the 100 volunteers, 49 were female and 51 were male. Their mean age was 39.8 years. Findings showed statistically significant prolongation of median distal motor latency (DML) and F-wave latency with age and reduction of median, ulnar, and sural sensory amplitudes as age increased. Gender differences showed consistent difference in the normal values for median, ulnar, and peroneal DMLs and respective F-wave latencies, which were significantly shorter in females. Sensory amplitudes of tested upper extremity nerves were significantly lower in males. Comparing with available data, our findings are similar to the Saudi population but significantly different from the American and multiethnic Malaysian populations. Pakistani individuals generally have significantly higher amplitudes and faster conduction velocities with similarities to South Asian studies.

Conclusions:

We recommend normative NCS parameters for commonly tested nerves for the Pakistani population, using standardized techniques to ensure highest quality testing and outcomes.

Keywords

Nerve conduction studies
normal values
normative data
practices standards
reference values

INTRODUCTION

Nerve conduction studies (NCS) are an important diagnostic tool in the assessment of peripheral nervous system disorders and helps in diagnosis, prognostication, and longitudinal monitoring of a disease process.[12] In order to identify abnormal values, a set of “normative” or “reference” values need to be determined.[34] The latter are derived from a healthy subject population that approximates the demographics of the patients. Age, gender, temperature, techniques, and possibly ethnicity may affect the results.

With the dearth of published data on reference values that can be widely used, most neurophysiology departments around the world tend to identify their own reference values[35] or use established Western values. The neurophysiology department at the Aga Khan University Hospital (AKUH), Karachi, was established over 20 years ago. The aim of our study is to help establish NCS normative data that could be applicable in the Pakistani population and can be used in neurophysiology departments around the country. We also aim to compare our findings with the existing published data from different populations.

MATERIALS AND METHODS

A prospective, descriptive study of willing healthy controls was undertaken over a 3-year period (2014–2017). Each individual was administered a standard screening questionnaire and only those individuals meeting the inclusion criteria were included in the study. Written consent was obtained. This study was approved by the Ethical Review Committee of the AKUH.

One hundred asymptomatic adult volunteers, over the age of 18 years, willing to consent, and without known sensory symptoms, neurologic disorders, or other medical issues that could affect peripheral nerves such as diabetes mellitus, thyroid disorders, Vitamin B12 deficiency, cancer with or without chemotherapy, or other such medications were enrolled. Participants underwent neurological examination, height and weight determinations, and NCS using standard methodology for sensory (median, ulnar, radial, median palmar, ulnar palmar, and sural) and motor (median, ulnar, peroneal, and tibial) nerves.

For NCS and electromyography, a Nicolet Viking machine was used. Low- and high-pass filters were set at 2 Hz and 10 kHz and 20 Hz and 3 kHz for motor studies and sensory studies, respectively, with a sweep speed of 2 ms/division.

Nerve conduction responses were recorded using standardized techniques. All responses were obtained using supramaximal stimulation and proper placement of electrodes. Data were collected for the following parameters: onset and peak latencies, amplitude, amplitude drop, conduction velocity (CV), and F-waves. All sensory nerves were examined antidromically. Amplitudes for the sensory nerve action potential (SNAP) were measured from the peak of the negative potential to the peak of the positive potential. SNAP peak and onset latencies were noted. Sensory median and ulnar nerves were stimulated at the wrist and recorded from the 2nd and 5th digits, respectively, at a distance of 14 cm. Distance for stimulation for palmar responses was 8 cm. The radial nerve was stimulated 10 cm proximal to the active electrode on the dorsolateral aspect of the distal forearm.

Median and ulnar motor nerves were tested with the active electrode over the motor point of the abductor pollicis brevis and the abductor digiti minimi muscles, respectively. In the lower limbs, for the tibial and peroneal nerves, the active electrodes were over the adductor hallucis and extensor digitorum brevis, respectively. The reference electrodes were placed on the tendon of the muscle in question. Distal stimulations were 8 cm proximal to the active electrode for motor median, ulnar, and peroneal nerves and 9 cm for the tibial nerve. The acceptable limb temperature for performing NCS was ≥32°C. In the event of cool limb temperatures, the participant was warmed up using hot water bags or a heating pad to maintain the temperature, as needed.

Statistical analysis

Statistical analysis was performed using IBM SPSS Statistics for Windows, Version 19.0. (Armonk, NY: IBM Corp). Continuous variables were reported as mean and standard deviation. Independent sample t-test was used to assess differences between sexes and age groups. Reference value was set to outside the mean ±2 standard deviations. P < 0.05 was taken as cutoff level for statistical significance.

RESULTS

Of the 100 healthy volunteers, 49 (49%) were female and 51 (51%) were male. Their mean age was 39.8 ± 12.3 years (range 18–67). Participants were grouped in the age groups of <30 (n = 24), 30–39 (n = 28), 40–49 (n = 20), and >50 (n = 28) years. Male and female differences were assessed. Normal values for motor nerve and sensory nerve conductions are summarized in Tables 1 and 2, respectively.

Table 1 Motor nerve conduction study findings of upper and lower limbs
Distance DML±SD (ms) DML 95th Amp±SD (µV) Amp 5th CV±SD (m/s) CV 5th F-wave±SD (ms) F-wave 95th
Median 8.0 3.1±0.40 3.8 10.5±2.8 6.2 58.7±4.3 51 24.9±2.1 29
Ulnar 8.0 2.5±0.30 3.1 10.4±2.0 7.4 61.3±3.9 54 25.3±2.2 29
Tibial 9.0 3.9±0.6 5.0 12.5±4.5 5.7 48.6±4.1 42 45.4±4.1 54
Peroneal 8.0 3.4±0.5 4.5 6.1±2.0 3.2 50.7±3.9 45 44.7±3.7 50

DML: Distal motor latency, Amp: Amplitude, CV: Conduction velocity, SD: Standard deviation, 95th: 95th percentile, 5th: 5thpercentile

Table 2 Sensory nerve conduction study findings of upper and lower limbs
Onset DL (95th) Mean±SD Peak DL (95th) Mean±SD Amp (5th) Mean±SD CV (5th) Mean±SD
Median
 Palmar 1.6 1.3±0.14 2.1 1.9±0.15 40.1 98±39.3 51.6 63±7.3
 Digit II 2.7 2.3±0.18 3.5 3.0±0.27 18.0 41±15.1 52.0 60.4±4.5
Ulnar
 Palmar 1.5 1.2±0.13 2.0 1.7±0.15 1 8.1 44.1±19.5 53.3 66.1±6.6
 Digit V 2.7 2.3±0.24 3.4 3.0±0.30 15.0 35.0±13.0 60.0±5.6
Radial - forearm 2.0 1.6±0.18 2.5 2.1±0.19 25.0 45.5±14.2 60.0 71.7±6.0
Sural - calf 3.0 2.4±0.3 3.8 3.2±0.32 12.0 22.5±8.8 44.0 57±6.3

DL: Distal latency, Amp: Amplitude, CV: Conduction velocity, SD: Standard deviation, 95th: 95th percentile, 5th: 5th percentile

Tables 3 and 4 show the variation in normal values of motor and sensory findings among various age groups.

Table 3 Motor nerve conduction study findings of upper and lower limbs grouped by age
Age DML (ms) 95th DML±SD Amp (µV) 5th Amp±SD CV (m/s) 5th CV±SD F-wave (ms)±SD F-wave 95th
Median (years)
 <30 3.7 3.0±0.32 7.0 11.0±2.5 52.2 59.6±3.4 25±2.2 29
 30-39 3.6 3.0±0.37 6.8 11.2±2.6 50.4 60.0±4.1 24±2.2 29
 40-49 4.0 3.2±0.36 6.2 10.2±2.5 51.0 58.1±4.7 25±1.4 28
 ≥50 4.0 3.2±0.43 4.6 10.0±3.3 51.0 57.8±5.0 26±2.0 29
P 0.02 0.33 0.36 0.01
Ulnar (years)
 <30 3.3 2.7±0.33 6.9 10.2±2.2 54 61.3±4.1 25.1±2.2 29
 30-39 3.1 2.4±0.28 7.2 11.0±2.3 54.4 61.1±3.7 25.1±2.4 30
 40-49 3.1 2.6±0.28 7.5 10.5±1.5 54.2 63.2±3.5 25.2±2.2 28
 ≥50 3.1 2.5±0.28 5.8 10.1±2.0 54 60.1±3.7 25.8±2.2 29
P 0.059 0.38 0.06 0.62
Tibial (years)
 <30 5.0 3.8±0.57 5.8 13.4±4.7 42.2 49.2±3.8 45.3±4.3 57.1
 30-39 5.0 4.0±0.55 5.7 14.5±5.1 42.0 49.4±4.5 43.9±4.1 54.1
 40-49 5.5 3.8±0.6 4.5 11.4±2.8 42.0 49.0±4.6 45.6±3.1 51.0
 ≥50 5.5 4.0±0.7 5.4 10.6±3.8 41.8 47.1±3.3 47±4.1 54.5
P 0.59 0.005 0.13 0.06
Peroneal (years)
 <30 5.2 3.6±0.7 2.9 6.6±2.3 44.2 50.4±3.8 44.1±3.2 49.7
 30-39 4.3 3.4±0.5 3.7 56.1±1.7 46.4 52.4±3.3 43.8±4.0 51.4
 40-49 4.2 3.4±0.4 3.2 5.8±1.7 46.0 50.3±3.2 44.1±4.1 54.7
 ≥50 4.4 3.4±0.52 2.4 5.7±2.2 44.0 49.6±4.5 46±3.3 51.2
P 0.64 0.45 0.04 0.12

DML: Distal motor latency, Amp: Amplitude, CV: Conduction velocity, SD: Standard deviation, 95th: 95th percentile, 5th: 5th percentile

Table 4 Sensory nerve conduction study findings of upper and lower limbs grouped by age
Age DL (ms) 95th Peak DL±SD Amp (µV) 5th Amp±SD CV (m/s) 5th CV±SD
Median digit II (years)
 <30 3.5 3.0±0.37 18.6 43.6±13.2 52 59.2±4.8
 30-39 3.4 3.0±0.24 34.4 51.0±16.2 53.4 61.7±4.0
 40-49 3.4 3.1±0.19 16.3 35.4±10 53 60.2±3.8
 ≥50 3.5 3.1±0.21 15.4 32.5±12.0 53 60.2±12
P 0.06 <0.0001 0.27
Ulnar digit V (years)
 <30 3.4 3.0±0.38 13.2 37.8±14.5 51 61.6±5.7
 30-39 3.4 3.0±0.21 22.9 39.5±11.6 53 61.2±5.3
 40-49 3.4 3.1±0.31 20.0 34.8±10.1 50 57.4±4.1
 ≥50 3.5 3.1±0.24 14.0 27.7±11.8 50.4 58.7±6.1
P 0.052 0.003 0.03
Radial (years)
 <30 2.5 2.1±0.18 24 47.0±16.7 60 71.4±6.1
 30-39 2.4 2.0±0.18 28.1 49.5±14.5 63 72.0±4.5
 40-49 2.8 2.1±0.24 30 43.5±11.6 57.1 71.5±7.0
 ≥50 2.6 2.1±0.19 30 41.6±12.5 55.3 72.0±6.5
P 0.38 0.18 0.97
Sural (years)
 <30 3.0 2.4±0.20 10.5 24.5±10.8 49 57.7±4.2
 30-39 3.6 3.1±0.27 15.4 26.2±8.2 45.8 57.7±4.2
 40-49 4.0 3.1±0.31 10.1 21.0±7.6 56 57.5±7.1
 ≥50 4.1 3.2±0.4 9.3 18.2±6.0 51 56.2±8.1
P 0.94 0.003 0.62

DL: Distal latency, Amp: Amplitude, CV: Conduction velocity, SD: Standard deviation, 95th: 95th percentile, 5th: 5th percentile

Variations with age

There is a significant increase in the median distal motor latency and F-wave latency with age (>40 years) [Table 3]. Median SNAP from digit II and ulnar SNAP from digit V showed significantly higher amplitudes in the younger age groups (<40 years). Sural sensory amplitudes also decreased with increasing age (P < 0.003) [Table 4]. Tibial motor amplitudes decreased with age (P 0.005). Although peroneal motor CVs statistically increased with age, the increase through age groups is not consistent and therefore not clinically significant.

Variations with gender

Gender differences (adjusted for height) showed consistent difference in the normal values for median, ulnar, and peroneal distal motor latencies and respective F-wave latencies, which were significantly shorter in females for median, ulnar, and peroneal nerves [Table 5]. No significant gender differences were noted for motor conduction velocities.

Table 5 Motor nerve conduction study findings of upper and lower limbs grouped by gender
Gender DL (ms) 95th DML±SD Amp (µV) 5th Amp±SD CV (m/s) 5th CV±SD F-wave (ms) 95th F-wave±SD
Median
 Male 4.0 3.3±0.36 6.2 10.3±2.90 51.0 58.7±4.76 28.6 25.5±1.89
 Female 3.6 2.9±0.35 7.4 10.6±2.81 51.3 58.7±4.0 29.1 24.3±2.21
P <0.001 0.058 0.98 0.003
Ulnar
 Male 3.2 2.7±0.29 7.2 10.3±2.08 54.0 60.7±3.90 29.0 26.1±1.94
 Female 3.1 2.5±0.29 7.3 10.7±2.11 54.0 62.0±3.85 28.5 24.5±2.36
P 0.001 0.33 0.24 <0.001
Tibial
 Male 5.0 4.0±0.63 7.6 12.2±3.73 43.0 48.0±3.45 53.3 46.4±3.50
 Female 5.4 4.0±0.60 6.4 12.8±5.29 43.0 49.4±4.68 55.0 44.5±4.53
P 0.72 0.51 0.09 0.02
Peroneal
 Male 4.7 3.6±0.52 3.2 6.2±2.02 44.6 51.8±4.32 51.2 46.3±3.24
 Female 4.5 3.3±0.54 3.0 5.9±2.07 45.5 53.2±3.76 50.0 43.1±3.66
P 0.002 0.50 0.08 <0.001

DML: Distal motor latency, Amp: Amplitude, CV: Conduction velocity, SD: Standard deviation, 95th: 95th percentile, 5th: 5th percentile

Sensory amplitudes of median (digit II), ulnar (digit V), and radial were significantly lower in males [Table 6]. Amplitude and peak latency of ulnar palmer responses was also significantly different in males, with a lower amplitude and longer latency (P = 0.03, amplitude: male = 40.2 ± 19.6 and female = 48.4 ± 18.8, peak latency: male = 1.8 ± 0.15 and female = 1.7 ± 0.14).

Table 6 Sensory nerve conduction study findings of upper and lower limbs grouped by gender
Gender Peak DL (ms) Amp (µV) CV (m/s)
95th ±SD 5th ±SD 5th ±SD
Median digit II
 Male 3.5 3.1±0.28 16.0 37.7±11.52 52.0 59.7±4.53
 Female 3.4 3.0±0.25 22.0 45.5±17.17 52.5 61.2±4.52
P 0.10 0.004 0.12
Ulnar digit V
 Male 3.4 3.1±0.27 14 30.8±10.51 50.0 59.0±5.34
 Female 3.4 3.0±0.30 15 39.2±14.0 52.0 60.7±5.87
P 0.02 0.001 0.07
Radial
 Male 2.5 2.2±0.18 24 40.9±12.30 58.5 71.1±5.92
 Female 2.4 2.1±0.21 31 50.34±14.59 61.5 72.53±6.07
P 0.26 0.001 0.22
Sural
 Male 3.9 3.2±0.34 11.6 21.74±8.92 43.0 56.3±6.06
 Female 3.8 3.2±0.30 11.0 23.38±8.73 43.5 57.4±7.11
P 0.78 0.35 0.40

95th: 95th percentile, 5th: 5th percentile. DL: Distal latency, Amp: Amplitude, CV: Conduction velocity, SD: Standard deviation

DISCUSSION

NCS are an important tool for the evaluation of peripheral nervous system disorders. The main aim of our study was to provide reference NCS values for commonly tested nerves in normal Pakistani adult volunteers and to compare with published normative values, using standardized techniques. Falck and Stalberg[6] determined that “Reference values in one laboratory can be used in others when techniques are standardized.” Normative data for NCS to our knowledge have not been formally performed previously in our population. The reference values currently used in Pakistan are either established by individual institutions based on a very small sample size or based on Western data. We determined that there are some differences between the two groups.

Our reference values were compared to normative nerve conduction values from other population-based studies that investigated asymptomatic healthy controls, using standardized techniques. The results of our study show similar findings to that described (taking variation in measurements techniques into consideration) in the Saudi and Indian population and somewhat to the Kuwaiti population[789] but significantly different for sensory studies in the American and multi-ethnic Malaysian population[101112] when comparing with published data [Table 7]. CVs in our participants were comparable to the CVs reported in a study from India;[13] however, we were not able to compare amplitudes as their measuring technique was baseline to peak. Pakistani individuals generally have significantly increased sensory amplitudes and faster conduction velocities. Sensory distal latencies were slightly increased which we believe could be related to the variations in distal distances used or whether onset or peak latency was used. For this reason, we opted to make note of both latencies.

Table 7 Comparison of current study data of motor and sensory nerves with published data from other regions of the world
Motor Present study AKUH (mean±SD) Albers (US) (range)[10] Rasheedi[8] (KFSH SA) (mean±SD) Kimura[12] (mean±SD) Fong (Malaysian)[11]Reference limits
Median nerve
 DML - 3.1±0.4 2.3-4.3 - 3.00±0.40 3.49±0.34 4.1
 MNCV 58.7±4.3 48-73 59±4.33 57.7±4.9 52
 CMAP A 10.5±2.8 3.0-20 10.4±2.27 7.0±3.0 7.4
Ulnar nerve
 DML 2.5±0.3 1.9-3.8 - 2.5±0.36 2.59±0.39 3.0
 MNCV 61.3±3.9 46-71 59.8±4.86 58.7±5.1 53
 CMAP A 10.4±2.0 5.7-22 10.9±1.96 5.7±2.0 7.0
Tibial nerve
 DML - 3.9±0.6 3.0-6.3 - 3.5±0.61 3.96±1.0 4.1
 MNCV 48.6±4.1 40-60 48.7±4.6 48.5±3.6 40
 CMAP A 12.5±4.5 3.0-30 12.1±3.30 5.8±1.9 7.5
Peroneal nerve
 DML - 3.4±0.5 3.3-6.4 - 3.7±0.5 3.77±0.86 4.2
 MNCV 50.7±3.9 39-58 50.9±3.86 48.3±3.9 44
 CMAP A 6.1±2.0 2.0-11 5.4±2.13 5.1±2.3 3.0
Sensory Present study AKUH peak DL for sensories (mean±SD) Present study AKUH onset DL for sensories (mean±SD) Albers[10] (US) (range) Rasheedi[8] (KFSH SA) onset DL (mean±SD) Kimura[12] onset DL (mean±SD) Fong (Malaysia)[11] mean±2SD*
Median nerve
 DL digit II 3.0±0.27 2.3±0.18 2.3-3.9 1.76±0.31 2.84±0.34
 SNCV 60.4±4.5 60.4±4.5 51-71 62.5±9.28 56.2±5.8 47
 SNAP A 41±15.1 41±15.1 15-90 59.47±25.76 38.5±15.6 7
Ulnar nerve
 DL digit V 3.0±0.30 2.3±0.24 2.3-3.7 1.69±0.25 2.54±0.29
 SNCV 60.0±5.6 60±5.6 49-77 66.85±8.77 54.8±5.3 48
 SNAP A 35±13 35±13 17-70 25.01±8.25 35.0±13.4 6
Radial nerve
 DL 2.1±0.19 1.6±0.18 2.30±0.29
 SNCV 71.7±6.0 71.7±6.0 67.16±6.62 50
 SNAP A 45.5±14.2 45.5±14.2 42.56±13.20 20
Sural nerve
 DL Lat 3.2±0.32 2.4±0.3 2.5-4.4
 SNCV 57±6.3 57±6.3 40-58 41
 SNAP A 22.5±8.8 22.5±8.8 5.0-50 7

DML: Distal motor latency, MNCV: Motor nerve conduction velocity, CMAP: Compound motor action potential, SD: Standard deviation, DL: Distal latency, SNCV: Sensory conduction velocity, SNAP: Sensory nerve action potential, *SNAP A by log transformation, AKUH: Aga Khan University Hospital, KFSH: King Faisal Specialist Hospital

Amplitude drop was also noted as the age increased [Table 4]. This could be explained secondary to the natural loss of axons with aging. Similar to previous studies,[14] SNAP amplitudes decreased with age, significantly for median, ulnar, and sural SNAPs. Females had consistently higher SNAP amplitudes compared to males, most significantly in upper-limb nerves. This is similar to findings described in other populations.[1516] Median and ulnar SNAP (digit II and V) showed statistically significant amplitude decrease in males [Table 6]. Bolton and Carter[17] suggested this to be possibly because of varying finger circumference. Variation in SNAP amplitude from other studies could also be because of different methods of measurement.[7] We used peak-to-peak amplitude measurement, the peak latency for distal latency, and onset latency for CV of sensory nerves studies. Males had higher normal values for median, ulnar, and peroneal F-wave latency, which has also been described in a study from India.[9]

Some of these differences may be due to body habitus, genetic factors, lifestyle, and dietary differences.[8] Furthermore, factors such as the filter setting of the high frequencies and low frequencies make significant difference in the NCS values; therefore, filter settings should be specified.[18] Albers[10] used filter settings of 2 Hz and 10 kHz and 20 Hz and 2 kHz for motor and sensory studies, respectively, for their laboratory.

Another important factor that can make a difference is the need for standardized techniques. They include accurate and standardized distal distances, supramaximal stimulation but preventing excessive stimulation or overstimulation. Temperature is an important factor. Electrode application and impedance is another technical factor to consider. Standardization of techniques ensures quality of nerve conduction studies. It helps in comparing studies over periods of time with easier comparison of outcome measures and effectiveness of treatment.[18]

There is considerable mention in literature about the effect of age, gender, height, and other individual related variables, but little information on how ethnicity affects the NCS. Fong et al.[11] have demonstrated the ethnic/racial differences in their article. Yet, others have failed to demonstrate that ethnicity[1920] makes a difference. Therefore, as suggested by Lahoria et al. “highly developed reference values with correction for applicable variables may be used for cohorts of mixed ethnicity.”[20]

Normative reference values of commonly tested peripheral nerves were established for a sample healthy adult population in Karachi, Pakistan. Values for sensory NCS for most nerves tested varied from published data.[101112] This study showed that amplitudes were higher and CVs were faster. Our data have similarities to the South Asian studies we reviewed. The motor studies, though, were comparable to reported normative nerve conduction values, with variations according to sex and age. Amplitude variations could be explained by the different methods of amplitude measurement, distal latency variations by differences in distal distances used, techniques and equipment settings, genetic factors, lifestyle, dietary differences, and possibly ethnicity. It is, therefore, highly recommended and encouraged to obtain our own reference values for NCS. It would be interesting to do a normal NCS for the South Asian population.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

REFERENCES

  1. , , , . Reference data for commonly used sensory and motor nerve conduction studies. Muscle Nerve. 2009;40:772-94.
    [Google Scholar]
  2. , , . Nerve conduction studies: Essentials and pitfalls in practice. J Neurol Neurosurg Psychiatry. 2005;76(Suppl 2):ii23-31.
    [Google Scholar]
  3. , , . AAEM minimonograph #47: Normative data in electrodiagnostic medicine.Ff. Muscle Nerve. 1997;20:4-14.
    [Google Scholar]
  4. , , , . Developing reference data for nerve conduction studies: An application of quantile regression. Muscle Nerve. 2009;40:763-71.
    [Google Scholar]
  5. , , , , , , . Electrodiagnostic reference values for upper and lower limb nerve conduction studies in adult populations. Muscle Nerve. 2016;54:371-7.
    [Google Scholar]
  6. , , . Motor nerve conduction studies: Measurement principles and interpretation of findings. J Clin Neurophysiol. 1995;12:254-79.
    [Google Scholar]
  7. , . Normative data of nerve conduction studies in the upper limb in Kuwait: Are they different from the western data? Med Princ Pract. 1998;7:203-8.
    [Google Scholar]
  8. , , , , , , . Normative nerve conduction study (NCS) Data in the Saudi population. P3.176, 2015 AAN annual meeting supplement. Neurology. 2015;84:82.
    [Google Scholar]
  9. , , , . Normative data of upper limb nerve conduction in Central India. Indian J Physiol Pharmacol. 2011;55:241-5.
    [Google Scholar]
  10. , . Nerve Conduction Manual, University of Michigan. Available from: https://wiki.med.umich.edu/download/attachments/66716003/SECTION04.pdf
    [Google Scholar]
  11. , , , , , . Effects of demographic and physical factors on nerve conduction study values of healthy subjects in a multi-ethnic asian population. Muscle Nerve. 2016;54:244-8.
    [Google Scholar]
  12. , . Electrodiagnosis in Diseases of Nerve and Muscle: Principles and Practice. Philadelphia: FA Davis; . p. :3.
    [Google Scholar]
  13. , , , . Reference values for nerve function assessments among a study population in northern India – III: Sensory and motor nerve conduction. Neurol Asia. 2010;15:39-54.
    [Google Scholar]
  14. , , , . Effect of aging on sensory nerve conduction study parameters. Muscle Nerve. 2004;29:716-20.
    [Google Scholar]
  15. , . Effects of gender and age on median and ulnar nerve sensory responses over ring finger. J Electromyogr Kinesiol. 2014;24:52-7.
    [Google Scholar]
  16. , , , , , , . The effects of age, gender, and body mass index on amplitude of sensory nerve action potentials: Multivariate analyses. Clin Neurophysiol. 2009;120:1683-6.
    [Google Scholar]
  17. , , . Human sensory nerve compound action potential amplitude: Variation with sex and finger circumference. J Neurol Neurosurg Psychiatry. 1980;43:925-8.
    [Google Scholar]
  18. , , , , , , . Establishing high-quality reference values for nerve conduction studies: A report from the normative data task force of the American Association of Neuromuscular and Electrodiagnostic Medicine. Muscle Nerve. 2016;54:366-70.
    [Google Scholar]
  19. , , . Race effect on nerve conduction studies: A comparison between 50 blacks and 50 whites. Arch Phys Med Rehabil. 1999;80:536-9.
    [Google Scholar]
  20. , , , . Reference Attributes of Nerve Conduction and Ethnicity: Comparison in Northern Plain Indians, Mexican Americans and Caucasians (P6.097) Neurology. 2014;82(10 Supplement):6.097.
    [Google Scholar]
Show Sections